# Triple Quadrupole Mass Spectrometer Cutaway Figure · Yila

> A cutaway of a triple quadrupole instrument in which ions travel left to right from an electrospray source through an ion funnel, two mass filters and a collision cell to a detector, with a pressure wedge beneath for teaching quantitative MS.

URL: https://yila.ai/templates/triple-quadrupole-mass-spectrometer-apparatus-figure

The figure shows how a tandem instrument carries ions from atmospheric pressure into high vacuum and selects them twice. The sample is sprayed and charged at the electrospray tip while desolvation gas dries the droplets. Ions pass the heated capillary and are focused by the ion funnel into Q1, which transmits one chosen precursor. In Q2 collision gas breaks it apart, and Q3 passes a chosen fragment on to the electron multiplier. A reader should come away understanding why every chamber along the axis is pumped on its own.

- **Electrospray source**: Capillary tip, Taylor cone and both desolvation gas streams sit at the far left, each named exactly once.
- **Heated capillary inlet**: Shade the heated tube in a warm colour and caption it as the boundary between atmosphere and vacuum.
- **Ion funnel**: Draw a stack of ring electrodes narrowing toward the exit, with a single leader line to the throat.
- **Q1 mass filter**: Four symmetric rods with a note that RF and DC are applied together to select the precursor ion.
- **Q2 collision cell**: State the rod set type and show the collision gas inlet; write collision-induced dissociation rather than a vague fragment caption.
- **Q3 mass filter**: Build it like Q1, mark RF plus DC again, and say that it selects the product ion.
- **Electron multiplier detector**: Place it at the end of the ion axis with its name kept clear of the housing outline.
- **Pumps and pressure gradient**: Pipe the rough pump to the first chamber, aim each turbomolecular pump at the chamber it evacuates, and print pressures at both wedge ends.

- Course handout, Paper mechanism figure, Academic poster, Grant proposal

- **Pressure falls in stages**: Differential pumping drops the pressure in steps across small apertures between chambers. The sample draws one smooth wedge and leaves the rough pump floating unconnected, so expect questions about how each stage is pumped.
- **How the three rod sets operate**: Q1 and Q3 filter by mass with RF plus DC, while Q2 is RF-only and simply transmits fragments. The sample marks RF and DC under Q1 alone, and calls Q2 a hexapole while drawing a quadrupole-like rod set.
- **Duplicated and garbled captions**: Taylor cone, ion funnel and turbomolecular pumps are each captioned twice, the upper gas label reads as garbled 'Desolvation gas as flow', and Q1 claims hyperbolic electrodes but shows round cylinders.
- **Match the scan mode**: For multiple reaction monitoring the legend should say Q1 picks the precursor and Q3 the product ion. Precursor or neutral loss scans set the two filters differently, so the arrow notes must change with them.

## FAQ

### Can I use this mass spectrometer figure directly in a paper?

Treat it as an AI-generated sketch for a methods figure. The sample repeats labels, garbles the desolvation gas caption and gives Q2 a name that does not match its rods, so check every part against the instrument you actually used before submitting.

### Can individual parts of the figure be changed?

Not element by element, and it is not a vector graphic. You can keep refining it by chatting in Yila, for example asking for a ring-electrode ion funnel or a piped rough pump, and the whole figure is regenerated from your instructions. Ask for one change per message so you can compare versions side by side.

### What file format do I get?

You get an AI-generated PNG image in 4:3 landscape, with the parts laid out along one horizontal ion axis, which suits a full-width figure or a single slide. If a journal wants vector art, redraw it from this layout in a drawing program.

### Does using this template cost anything?

Reading this page and viewing the sample are free of charge. Generating and refining a figure in Yila consumes credits, and every new account receives 2,500 credits, enough to build a version matching your own instrument and adjust it. Gather your corrections before generating to save rounds.

### Can it illustrate a multiple reaction monitoring experiment?

Yes. Say which precursor Q1 holds fixed and which product ions Q3 monitors, and Yila adds m/z callouts and a selection sketch beside the two filters while keeping the collision cell between them.

### Could the source be switched to APCI?

Yes. Ask for a heated nebuliser and a corona discharge needle in place of the electrospray capillary. The ion funnel, the three rod sets and the vacuum stages stay as they are, and only the left-hand source is redrawn. Say whether you want the solvent flow drawn as well.

---

- [Triple Quadrupole Mass Spectrometer Cutaway Figure](https://yila.ai/templates/triple-quadrupole-mass-spectrometer-apparatus-figure)
- [llms.txt](https://yila.ai/llms.txt)
