# Exploded Wearable Patch on a Mouse for Sensing and Drug Release · Yila

> A device overview: a mouse wears a flexible patch that is pulled apart into an exploded layer stack, while three lower panels explain temperature sensing, pH sensing and voltage-triggered drug release. It suits soft-electronics and closed-loop dosing papers.

URL: https://yila.ai/templates/wearable-mouse-apparatus-figure

At upper left a white mouse carries a green flexible patch with a chip and a round component on its back, and a dashed line leads to an exploded stack: a clear encapsulation sheet with a round element, a sensor array of gold components, a substrate with traces, a position labelled tiny battery, and a pinned wireless chip. Three panels below show a thermistor with a falling resistance–temperature curve, two electrodes with a beaker inset for pH, and a reservoir of orange drug particles with a close-up of release through a polymer. Readers should see how one patch monitors physiology and doses on demand.

- **Mouse with patch**: The patch sits on the mouse's back between the shoulders; note the attachment method and how long it is worn.
- **Encapsulation**: The clear top sheet carrying a round component; name the encapsulant and any breathing holes in it.
- **Sensor array**: The circuit layer of gold components; list the sensor types and their positions in the label.
- **Tiny battery**: Its leader points to the substrate edge with no battery drawn; mark the real position of the cell when you revise.
- **Wireless chip**: The pinned square chip at the bottom of the stack; write the link used, such as Bluetooth or near-field communication.
- **Thermistor panel**: Resistance falls as temperature rises in the inset curve; label it as a negative temperature coefficient element.
- **pH panel**: Two electrodes and a beaker inset; relabel them as working and reference electrodes mounted on the patch.
- **Drug-release reservoir**: A well of orange particles with a close-up of drug leaving the polymer; name the drug and the polymer.

- Paper mechanism figure, Graphical abstract, Defense slides, Grant proposal

- **Layer order and skin side**: The sensor array sits under the encapsulation and above the substrate, far from the skin. Reviewers will ask how the sensing face touches the skin and why the drug reservoir is missing from the stack.
- **pH sensing principle**: The pH inset shows protons travelling between electrodes in a beaker, which does not match potentiometric pH sensing. Show a working electrode whose potential shifts with pH, measured against a reference electrode.
- **Power source**: The tiny battery leader points at the substrate edge and no cell is visible. Reviewers will look for the power strategy, the operating time between charges, and whether the device weight suits a mouse.
- **Release control**: Voltage-triggered release needs the polymer's response mechanism, the trigger threshold and the release kinetics. Reviewers will also ask whether sensor readings actually drive dosing in a closed loop or only run alongside it.

## FAQ

### Can I put this mouse patch figure straight into a paper?

Use it as a draft device overview. It is AI-generated, so the layer order, circuitry and electrodes are not drawn from your design files. Check the stack and sensing principles, fix the battery leader and mark the figure as schematic in its caption before submission.

### Can I edit one layer or one sensor?

Layers cannot be selected and edited individually, and the image is not a vector graphic. Describe the change in a Yila chat, for example adding a glucose sensor or replacing the battery with a wireless power coil, and the whole figure is regenerated around it. The other panels keep their style.

### What format is the download?

An AI-generated PNG in landscape: mouse and exploded stack above, three function panels below. If a journal needs vector files, redraw the layout in illustration software from this reference, keeping the dashed link between the mouse and the stack.

### Is there any cost?

Opening this page and viewing the sample costs nothing. Generating and each revision in Yila consume credits, and newly registered accounts receive 2,500 credits, enough to try a few layer orders and colour schemes. Viewing samples never uses credits.

### My patch goes on a rat or a human arm. Can the subject change?

Yes. State the wearer and the body site, such as a rat's back or a human forearm, and Yila redraws the subject at a suitable patch scale. The function panels can follow your own list of sensors and actuators. Keep the exploded stack unchanged.

### Can I show data streaming to a phone?

Yes. Ask for a signal arrow from the wireless chip to a phone or receiver with a simple live trace on its screen. If your paper is about closed-loop dosing, have the receiver send a command back to trigger the release panel. A phone icon is enough; avoid screenshots.

---

- [Exploded Wearable Patch on a Mouse for Sensing and Drug Release](https://yila.ai/templates/wearable-mouse-apparatus-figure)
- [llms.txt](https://yila.ai/llms.txt)
